Masterflex® L/S® Spooled Pump Tubing, PharMed® BPT, Avantor®
Protect your light-sensitive samples.
- Genuine Masterflex® tubing undergoes robust testing to provide optimal performance / pump life hours with peristaltic pump equipment
- Precision extruded to tight tolerances for high repeatability, accuracy and reproducibility
- Global market leader in range of formulations for most extensive chemical compatibility
- Single-use custom lengths and configurations available to minimize downtime
- Regulatory approvals to match your unique application
- Unique packaging options include packs, cases, and spools for customer-friendly ordering and delivery
Applications: Cell and tissue culture work, pharmaceutical, light-sensitive samples
Characteristics: Nontoxic, nonhemolytic, extremely low permeability, resists acids, bases, and oxidizing agents; heat-sealable, bondable, formable, opaque beige
Spooled pump tubing provides continuous lengths of pump tubing on convenient, manageable spools that are easy to transport and require less storage space than the equivalent amount of individual tubing coils.
For custom tubing lengths and configurations, please contact us. We can provide the tubing type, length, and quantity you need.
- Environmentally Preferable:
- Catalog No:
- MFLX95687-24
- MFLX95687-15
- MFLX95687-35
- MFLX95687-14
- MFLX95687-16
- MFLX95687-18
- MFLX95687-17
- MFLX95687-36
- Model:
- 95687-24
- 95687-15
- 95687-35
- 95687-14
- 95687-16
- 95687-18
- 95687-17
- 95687-36
- Length per pack:
- 91.4 m (300 ft.)
- 121.9 m (400 ft.)
- 91.4 m (300 ft.)
- 152.4 m (500 ft.)
- 152.4 m (500 ft.)
- 121.9 m (400 ft.)
- 152.4 m (500 ft.)
- 30.4 m (100 ft.)
- Max. Pressure:
- 2.7 bar (40 psi)
- 2.7 bar (40 psi)
- 2.4 bar (35 psi)
- 2.7 bar (40 psi)
- 2.7 bar (40 psi)
- 1 bar (15 psi)
- 1.4 bar (20 psi)
- 1.4 bar (20 psi)
- Min. Temperature:
- –51 °C (–60 °F)
- –51 °C (–60 °F)
- –51 °C (–60 °F)
- –51 °C (–60 °F)
- –51 °C (–60 °F)
- –51 °C (–60 °F)
- –51 °C (–60 °F)
- –51 °C (–60 °F)
- Max. Temperature:
- 132 °C (270 °F)
- 132 °C (270 °F)
- 132 °C (270 °F)
- 132 °C (270 °F)
- 132 °C (270 °F)
- 132 °C (270 °F)
- 132 °C (270 °F)
- 132 °C (270 °F)
- Min. temperature (dynamic):
- –20 °C (–4 °F)
- –20 °C (–4 °F)
- –20 °C (–4 °F)
- –20 °C (–4 °F)
- –20 °C (–4 °F)
- –20 °C (–4 °F)
- –20 °C (–4 °F)
- –20 °C (–4 °F)
- Max. temperature (dynamic):
- 100 °C (212 °F)
- 100 °C (212 °F)
- 100 °C (212 °F)
- 100 °C (212 °F)
- 100 °C (212 °F)
- 100 °C (212 °F)
- 100 °C (212 °F)
- 100 °C (212 °F)
- Max. Vacuum:
- 660 mm Hg (26" Hg)
- 660 mm Hg (26" Hg)
- 660 mm Hg (26" Hg)
- 660 mm Hg (26" Hg)
- 660 mm Hg (26" Hg)
- 510 mm Hg (20" Hg)
- 510 mm Hg (20" Hg)
- 610 mm Hg (24" Hg)
- Pump series:
- L/S
- L/S
- L/S
- L/S
- L/S
- L/S
- L/S
- L/S
- Regulatory approvals:
- FDA;Non-DEHP;RoHS;USP
- FDA;Non-DEHP;RoHS;USP
- FDA;Non-DEHP;RoHS;USP
- FDA;Non-DEHP;RoHS;USP
- FDA;Non-DEHP;RoHS;USP
- FDA;Non-DEHP;RoHS;USP
- FDA;Non-DEHP;RoHS;USP
- FDA;Non-DEHP;RoHS;USP
- Sterilization:
- Autoclave, Ethylene Oxide, Gamma Irradiation up to 2,5 Mrad
- Autoclave, Ethylene Oxide, Gamma Irradiation up to 2,5 Mrad
- Autoclave, Ethylene Oxide, Gamma Irradiation up to 2,5 Mrad
- Autoclave, Ethylene Oxide, Gamma Irradiation up to 2,5 Mrad
- Autoclave, Ethylene Oxide, Gamma Irradiation up to 2,5 Mrad
- Autoclave, Ethylene Oxide, Gamma Irradiation up to 2,5 Mrad
- Autoclave, Ethylene Oxide, Gamma Irradiation up to 2,5 Mrad
- Autoclave, Ethylene Oxide, Gamma Irradiation up to 2,5 Mrad
- Sterilisation method autoclave:
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Sterilisation method EtO:
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Sterilisation method gamma:
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Suction lift H₂O:
- 8.8 m (29 ft.)
- 8.8 m (29 ft.)
- 8.8 m (29 ft.)
- 8.8 m (29 ft.)
- 8.8 m (29 ft.)
- 6.7 m (22 ft.)
- 6.7 m (22 ft.)
- 8.3 m (27 ft.)
- Warranty:
- Out of box
- Out of box
- Out of box
- Out of box
- Out of box
- Out of box
- Out of box
- Out of box
- Tubing materialTubing int.ØHose barb sizeL/S Masterflex Tubing SizeMaximum Flow Rate
- L/S® Spooled Precision Pump Tubing, PharMed® BPT, L/S 14; 500 ftL/S® Spooled Precision Pump Tubing, PharMed® BPT, L/S 14; 500 ftPharMed® BPT1.60 mm (0.063")0.0625"14130 ml/minEach (500Feet)$2,690.00CE certificate
Specifications
Model95687-14Environmentally PreferableLength per pack152.4 m (500 ft.)Max. Pressure2.7 bar (40 psi)Min. Temperature–51 °C (–60 °F)Max. Temperature132 °C (270 °F)Min. temperature (dynamic)–20 °C (–4 °F)Max. temperature (dynamic)100 °C (212 °F)Max. Vacuum660 mm Hg (26" Hg)Pump seriesL/SRegulatory approvalsFDA;Non-DEHP;RoHS;USPSterilizationAutoclave, Ethylene Oxide, Gamma Irradiation up to 2,5 MradSterilisation method autoclaveYesSterilisation method EtOYesSterilisation method gammaYesSuction lift H₂O8.8 m (29 ft.)WarrantyOut of box - L/S® Spooled High-Performance Precision Pump Tubing, PharMed® BPT, L/S 15; 400 ftL/S® Spooled High-Performance Precision Pump Tubing, PharMed® BPT, L/S 15; 400 ftPharMed® BPT4.80 mm (0.189")0.1875"151100 ml/minEach (400Feet)$2,390.00CE certificate
Specifications
Model95687-15Environmentally PreferableLength per pack121.9 m (400 ft.)Max. Pressure2.7 bar (40 psi)Min. Temperature–51 °C (–60 °F)Max. Temperature132 °C (270 °F)Min. temperature (dynamic)–20 °C (–4 °F)Max. temperature (dynamic)100 °C (212 °F)Max. Vacuum660 mm Hg (26" Hg)Pump seriesL/SRegulatory approvalsFDA;Non-DEHP;RoHS;USPSterilizationAutoclave, Ethylene Oxide, Gamma Irradiation up to 2,5 MradSterilisation method autoclaveYesSterilisation method EtOYesSterilisation method gammaYesSuction lift H₂O8.8 m (29 ft.)WarrantyOut of box - L/S® Spooled Precision Pump Tubing, PharMed® BPT, L/S 16; 500 ftL/S® Spooled Precision Pump Tubing, PharMed® BPT, L/S 16; 500 ftPharMed® BPT3.10 mm (0.122")0.125"16480 ml/minEach (500Feet)$2,530.00CE certificate
Specifications
Model95687-16Environmentally PreferableLength per pack152.4 m (500 ft.)Max. Pressure2.7 bar (40 psi)Min. Temperature–51 °C (–60 °F)Max. Temperature132 °C (270 °F)Min. temperature (dynamic)–20 °C (–4 °F)Max. temperature (dynamic)100 °C (212 °F)Max. Vacuum660 mm Hg (26" Hg)Pump seriesL/SRegulatory approvalsFDA;Non-DEHP;RoHS;USPSterilizationAutoclave, Ethylene Oxide, Gamma Irradiation up to 2,5 MradSterilisation method autoclaveYesSterilisation method EtOYesSterilisation method gammaYesSuction lift H₂O8.8 m (29 ft.)WarrantyOut of box - L/S® Spooled Precision Pump Tubing, PharMed® BPT, L/S 17; 500 ftL/S® Spooled Precision Pump Tubing, PharMed® BPT, L/S 17; 500 ftPharMed® BPT6.40 mm (0.252")0.25"171700 ml/minEach (500Feet)$3,420.00CE certificate
Specifications
Model95687-17Environmentally PreferableLength per pack152.4 m (500 ft.)Max. Pressure1.4 bar (20 psi)Min. Temperature–51 °C (–60 °F)Max. Temperature132 °C (270 °F)Min. temperature (dynamic)–20 °C (–4 °F)Max. temperature (dynamic)100 °C (212 °F)Max. Vacuum510 mm Hg (20" Hg)Pump seriesL/SRegulatory approvalsFDA;Non-DEHP;RoHS;USPSterilizationAutoclave, Ethylene Oxide, Gamma Irradiation up to 2,5 MradSterilisation method autoclaveYesSterilisation method EtOYesSterilisation method gammaYesSuction lift H₂O6.7 m (22 ft.)WarrantyOut of box - L/S® Spooled Precision Pump Tubing, PharMed® BPT, L/S 18; 400 ftL/S® Spooled Precision Pump Tubing, PharMed® BPT, L/S 18; 400 ftPharMed® BPT7.90 mm (0.311")0.375"182300 ml/minEach (400Feet)$2,780.00CE certificate
Specifications
Model95687-18Environmentally PreferableLength per pack121.9 m (400 ft.)Max. Pressure1 bar (15 psi)Min. Temperature–51 °C (–60 °F)Max. Temperature132 °C (270 °F)Min. temperature (dynamic)–20 °C (–4 °F)Max. temperature (dynamic)100 °C (212 °F)Max. Vacuum510 mm Hg (20" Hg)Pump seriesL/SRegulatory approvalsFDA;Non-DEHP;RoHS;USPSterilizationAutoclave, Ethylene Oxide, Gamma Irradiation up to 2,5 MradSterilisation method autoclaveYesSterilisation method EtOYesSterilisation method gammaYesSuction lift H₂O6.7 m (22 ft.)WarrantyOut of box - L/S® Spooled High-Performance Precision Pump Tubing, PharMed® BPT, L/S 24; 300 ftL/S® Spooled High-Performance Precision Pump Tubing, PharMed® BPT, L/S 24; 300 ftPharMed® BPT6.40 mm (0.252")0.25"241800 ml/minEach (300Feet)$2,430.00CE certificate
Specifications
Model95687-24Environmentally PreferableLength per pack91.4 m (300 ft.)Max. Pressure2.7 bar (40 psi)Min. Temperature–51 °C (–60 °F)Max. Temperature132 °C (270 °F)Min. temperature (dynamic)–20 °C (–4 °F)Max. temperature (dynamic)100 °C (212 °F)Max. Vacuum660 mm Hg (26" Hg)Pump seriesL/SRegulatory approvalsFDA;Non-DEHP;RoHS;USPSterilizationAutoclave, Ethylene Oxide, Gamma Irradiation up to 2,5 MradSterilisation method autoclaveYesSterilisation method EtOYesSterilisation method gammaYesSuction lift H₂O8.8 m (29 ft.)WarrantyOut of box - L/S® Spooled High-Performance Precision Pump Tubing, PharMed® BPT, L/S 35; 300 ftL/S® Spooled High-Performance Precision Pump Tubing, PharMed® BPT, L/S 35; 300 ftPharMed® BPT7.90 mm (0.311")0.375"352600 ml/minEach (300Feet)$2,650.00CE certificate
Specifications
Model95687-35Environmentally PreferableLength per pack91.4 m (300 ft.)Max. Pressure2.4 bar (35 psi)Min. Temperature–51 °C (–60 °F)Max. Temperature132 °C (270 °F)Min. temperature (dynamic)–20 °C (–4 °F)Max. temperature (dynamic)100 °C (212 °F)Max. Vacuum660 mm Hg (26" Hg)Pump seriesL/SRegulatory approvalsFDA;Non-DEHP;RoHS;USPSterilizationAutoclave, Ethylene Oxide, Gamma Irradiation up to 2,5 MradSterilisation method autoclaveYesSterilisation method EtOYesSterilisation method gammaYesSuction lift H₂O8.8 m (29 ft.)WarrantyOut of box - L/S® Spooled High-Performance Precision Pump Tubing, PharMed® BPT, L/S 36; 100 ftL/S® Spooled High-Performance Precision Pump Tubing, PharMed® BPT, L/S 36; 100 ftPharMed® BPT9.70 mm (0.382")0.375"363400 ml/minEach (100Feet)$1,060.00CE certificate
Specifications
Model95687-36Environmentally PreferableLength per pack30.4 m (100 ft.)Max. Pressure1.4 bar (20 psi)Min. Temperature–51 °C (–60 °F)Max. Temperature132 °C (270 °F)Min. temperature (dynamic)–20 °C (–4 °F)Max. temperature (dynamic)100 °C (212 °F)Max. Vacuum610 mm Hg (24" Hg)Pump seriesL/SRegulatory approvalsFDA;Non-DEHP;RoHS;USPSterilizationAutoclave, Ethylene Oxide, Gamma Irradiation up to 2,5 MradSterilisation method autoclaveYesSterilisation method EtOYesSterilisation method gammaYesSuction lift H₂O8.3 m (27 ft.)WarrantyOut of box